-40%

DC 7V-30V 1-channel Trigger Switch Turn On Off Board Dual Switch Trigger Module

$ 2.24

  • Brand: Unbranded
  • EAN: Does not apply
  • UPC: Does not apply
  • gtin13: Does not apply

Description

Categories DC 7V-30V 1-channel Trigger Switch Turn On Off Board Dual Switch Trigger Module Description Product features: 1. It can be applied to work industry equipment, with infrared sensor to realize adding material when it is short of material and stopping when it is full of material. 2. It can be applied to water level control, with float switch to start the pump to drain when full of water, and stop when short of water. 3. It can be applied to water tower water level maintenance, with float switch to realize adding water when water is short and stopping when full. 4. Can be applied to the discharge machine to control the length of the discharge line. 5. With power supply reversal protection function, the module will not work when the power supply is connected to the wrong positive and negative. Product parameters: 【Name】Silicon controlled output type double key switch module 【Function】ON key to start the load work, OFF key to stop the load work. Input low voltage DC, output controllable 220V. 【Voltage】7V-30V at the input 【Working current】20mA 【Standby current】10mA 【Input mode】level signal, effective above 15mS, high and low level mode can be set by jumper. [Output mode] can be connected to the T1-T2 end of the silicon control, wired in series with the mains load can be. Output capacity] BT16-600 thyristor is used, the allowable current is 16A and voltage is 600v. Size】58*32*25(L*W*Hmm) 【Weight】20g 【Working Temperature】-40~+85C 【Working Humidity】0~90%RH no condensation 【Reverse protection】This module has the power supply connection reverse protection function, when the power supply positive and negative connection wrong module will not work. Setting instructions; High level / low level switching when the jumper is on the L side, X01 X02 are valid for low level When the jumper is on the H side, X01 X02 are active high SET Off pri jumper is used to set the Off function preference, when Off preference is needed, short the solder joint here. Normal mode. [Start] and [Stop] are equal, regardless of whether the other key is pressed, press [Start] to start and press [Stop] to stop. Off takes priority. When [Stop] key is pressed, it will stop, and pressing Start key is invalid. When the [Stop] key is released, it will not start even if the [Start] key is pressed. To start you have to release - then press the [Start] key. Product list: 1* Module DC 7V-30V 1-channel Trigger Switch Turn On Off Board Dual Switch Trigger Module Description Product features: 1. It can be applied to work industry equipment, with infrared sensor to realize adding material when it is short of material and stopping when it is full of material. 2. It can be applied to water level control, with float switch to start the pump to drain when full of water, and stop when short of water. 3. It can be applied to water tower water level maintenance, with float switch to realize adding water when water is short and stopping when full. 4. Can be applied to the discharge machine to control the length of the discharge line. 5. With power supply reversal protection function, the module will not work when the power supply is connected to the wrong positive and negative. Product parameters: 【Name】Silicon controlled output type double key switch module 【Function】ON key to start the load work, OFF key to stop the load work. Input low voltage DC, output controllable 220V. 【Voltage】7V-30V at the input 【Working current】20mA 【Standby current】10mA 【Input mode】level signal, effective above 15mS, high and low level mode can be set by jumper. [Output mode] can be connected to the T1-T2 end of the silicon control, wired in series with the mains load can be. Output capacity] BT16-600 thyristor is used, the allowable current is 16A and voltage is 600v. Size】58*32*25(L*W*Hmm) 【Weight】20g 【Working Temperature】-40~+85C 【Working Humidity】0~90%RH no condensation 【Reverse protection】This module has the power supply connection reverse protection function, when the power supply positive and negative connection wrong module will not work. Setting instructions; High level / low level switching when the jumper is on the L side, X01 X02 are valid for low level When the jumper is on the H side, X01 X02 are active high SET Off pri jumper is used to set the Off function preference, when Off preference is needed, short the solder joint here. Normal mode. [Start] and [Stop] are equal, regardless of whether the other key is pressed, press [Start] to start and press [Stop] to stop. Off takes priority. When [Stop] key is pressed, it will stop, and pressing Start key is invalid. When the [Stop] key is released, it will not start even if the [Start] key is pressed. To start you have to release - then press the [Start] key. Product list: 1* Module